Frame Ties With Drip

Stainless Frame Ties with Drip

Frame ties do two critical jobs:
They secure the brickwork to a steel or concrete frame, and they stop wind-driven rain reaching the inner leaf.
The drip feature on these ties breaks capillary action, forcing water to drop harmlessly back into the cavity—exactly what NHBC and PD 6697 expect from a modern façade.


Which tie fits your cavity?

Typical applicationGo-to tieCavity rangeLink*
Brickwork to SFS studsVista VE7D series50–250 mmVE7D range
Heavy wind loads / movement slotAncon SDV75–250 mmSDV 150 mm
General purpose brick-to-concreteAncon SDB100–275 mmSDB 200 mm

*Links jump straight to the boxed length on Spechunter.

Not sure which length? Call our technical desk on 0118 922 7941—we’ll size your ties while you’re on the phone.


Key features

  • Grade 304 stainless (316 optional) – 60-year design life and no bi-metallic staining.

  • Pressed drip or deep swage sheds water before it can reach the inner leaf.

  • Movement slots (SDV) absorb ±23 mm differential between brickwork and frame.

  • Meets PD 6697 Table 12 density – 2.5 ties/m² plus extras at openings.

Pair with red insulation-retaining clips to keep boards tight to the inner leaf.


Installation essentials

  1. Density – 2.5 ties/m² (450 mm vertical × 900 mm horizontal).

  2. Embedment – 50 ± 10 mm into the bed joint; seat the drip midway in the cavity.

  3. Fixing to frame – use stainless concrete & masonry screws through the tie’s 6.5 mm hole or slot.

  4. Compression sleeves – over 150 mm cavities add a compression sleeve to stop tie whip.

Never bed the drip into mortar—its job is to stay free so water falls away.


Frequently asked questions

Why choose a tie with a drip?

The drip interrupts water tracking along the steel into the inner skin, protecting insulation and finishes—essential on rainscreen or fair-face brick façades.

Can I mix stainless ties with galvanised screws?

Avoid mixing grades externally; match stainless to stainless to prevent staining.

Are VE7D ties suitable above 18 m?

Yes—stainless ties and fixings meet Regulation 7(2) for non-combustible components in external walls.

How many boxes do I need?

Wall area × 2.5 ÷ 250 (ties/box). Example: 120 m² façade → 1 200 ties → 5 boxes.

Is next-day delivery guaranteed?

Order before noon, spend £200 ex-VAT and check our delivery information for remote-area surcharges.


Complete your façade restraint package

Need PD 6697 spacing calcs or BIM objects? Contact us or ring 0118 922 7941—Spechunter will chase down every detail.

Spechunter.co.uk – Chasing down specialist construction specifications since 1988. Fact checked and updated May 2025.

...
Showing 1 - 9 of 22 items