- Home
- Concealed Weepholes
Concealed Weepholes
Concealed Weep Holes – Vent Walls • Drain Cavities • Keep the Façade Clean
Traditional open weep vents do the job—and advertise it. Concealed weep holes give you all the moisture drainage and NHBC compliance without the visual clutter. Slide a colour-matched Rytweep® or Timloc Invisiweep® tube into the perp joint, trim flush and the only thing you’ll see is perfect brickwork.
Order before 12 : 00 and spend £200 ex-VAT for free next-working-day delivery. Need take-offs? Call our building-envelope desk on 0118 922 7941.
Why choose concealed vents?
Discreet aesthetics
Face dimensions just 7 × 65 mm vanish in the mortar line—ideal for heritage brick, glazed façades and premium homes.
Fully NHBC & BBA accepted
4 mm internal path meets the 3 : 1 water-drop test and 25 mm minimum cavity penetration set out in NHBC Chapter 6.1.
Fire-safe options
Invisiweep A1 zinc satisfies Building Regs for external walls over 11 m; pair with non-combustible extension tubes.
Fast to install
Push-fit body, clip-on baffle and snap-off front tab—one vent in under 20 seconds.
Our concealed weep-hole range
Product | Material | Colours | Link | Box Qty |
---|---|---|---|---|
Rytweep® | ABS | Buff • Clear • Terracotta | Browse | 200 |
Rytweep® Extension Tube | ABS | Clear | Add | 200 |
Invisiweep® | Polypropylene | Black • Blue-black • Buff • Brown • Grey • Clear • Terracotta • White | See range | 200 |
Invisiweep® A1 Metal | Zinc | Natural | A1 Zinc | 50 |
500 mm Extension Tube | PP or Zinc | Clear / Metal | Add | Single |
Need standard vents? Explore Full-Height Weep Holes or Non-Combustible Weeps.
Where to install weep holes
Above cavity trays – over lintels, bay windows and parapets; team with our Timloc Inter-Loc trays.
At floor edges – one per 450 mm run behind ARC Party-Wall DPC Horizontal barriers.
Retaining walls – every brick course if hydrostatic pressure is a risk; use extension tubes to reach face brick.
Vent spacing rule: 2 bricks (450 mm) apart, minimum two vents per tray/run.
Installation in three quick steps
Insert tube deep enough to project 10 mm past insulation; cut off excess.
Clip on baffle (Invisiweep) or leave integral upstand (Rytweep) to shed any wind-driven rain.
Point flush with surrounding mortar—logo tab snaps off after curing.
Top tip: Keep tubes free of mortar snots—drop a clear extension tube through the cavity to catch debris, then withdraw after pointing.
Frequently asked questions
Do concealed weeps reduce airflow?
No. The 4 mm x 9 mm internal path exceeds NHBC’s 165 mm² open area requirement.
How many per opening?
Minimum two—one at each jamb. Wider openings need additional vents each 450 mm.
Can I retro-fit in existing brickwork?
Yes—rake out the perp joint, drill a 7 mm hole to the cavity and push-fit a single-vent pack.
Are they suitable above 18 m?
Only the A1 metal version (zinc) complies with Regulation 7(2); plastic weeps must stop at 18 m.
Next-day delivery—any catches?
Order before noon, spend £200 ex-VAT and see our delivery information for postcode exceptions.
Complete the moisture-management package
Cavity trays – Pre-Formed DPC
Parapet flashings – Hyload High-Bond DPC
Bed-joint reinforcement – Brick Mesh for crack-free openings.
Need NHBC certs or CAD details? Contact us or phone 0118 922 7941—Spechunter will chase down the spec for you.
Spechunter.co.uk – Chasing down specialist construction specifications since 1988. Fact Checked and Updated May 2025.
...