Type 3 Wall Ties
The Everyday Choice for Low-Rise Housing
Type 3 wall ties slot neatly between light-duty Type 4 and general-purpose Type 2. They’re rated for ≤2.5-storey housing or sheltered urban sites where wind loads are modest yet a little extra capacity over Type 4 is welcome. The classic double-triangle profile keeps the tie rigid under compression, and the pressed drip stops rainwater tracking to the inner leaf.
Order before 12:00 and spend £200 ex-VAT for free next-day delivery. Need tie spacing calcs? Call 0118 922 7941—we’ll size them while you wait.
Quick-order chart – pick by cavity width
Cavity (mm) | Tie & length | Box qty | Link |
---|---|---|---|
50 – 75 | Ancon DT150 150 mm | 250 | DT150 |
76 – 100 | Ancon DT225 225 mm | 250 | DT225 |
101 – 125 | Vista V26 250 mm | 250 | V26-250 |
126 – 150 | Vista V26 275 mm | 250 | V26-275 |
151 – 175 | Vista V26 300 mm | 250 | V26-300 |
Why builders still love double-triangle ties
0.55 kN tension / compression—ideal for houses and small apartment blocks.
Tangle-free shape—pull one tie from the bucket, no knots to undo.
Pressed drip centred in the cavity prevents moisture bridging.
Grade 304 stainless as standard; 316 available to order for coastal sites.
2.5 ties/m² density (450 × 900 mm grid) keeps calculations simple.
Clip on our red insulation-retaining clips to keep partial-fill batts flush against the inner leaf.
Installation checklist
Spacing: 450 mm vertical × 900 mm horizontal (2.5/m²); double within 150 mm of openings and movement joints.
Embedment: 50 ± 10 mm in each leaf. Seat the drip mid-cavity.
Mortar class: M4 (1:1:6) or stronger to satisfy PD 6697 pull-out values.
Cavities > 150 mm: slip a stainless compression sleeve over the tie to stop whip.
Movement joints: every 10 – 12 m, introduce stainless movement ties instead of standard ties.
Frequently asked questions
When should I specify Type 3 over Type 4?
Whenever the building is > 10 m tall or located in a “moderate” wind zone (BS 6399 / Eurocode C2). Type 4 covers single- or two-storey dwellings in sheltered suburbs only.
Can I mix Vista and Ancon double-triangle ties on one elevation?
Yes, provided they all meet Type 3 classification and you keep the density at 2.5/m².
Are galvanised Type 3 ties acceptable above DPC?
No—external masonry must be stainless under PD 6697.
Delivery cut-off?
Order by noon, meet the £200 ex-VAT threshold and see our delivery information for postcode exceptions.
Related items to drop in your basket
General-purpose ties – Type 2 Wall Ties
Heavy-duty restraint – Type 1 Wall Ties
Bed-joint reinforcement – Ladder Mesh
Pre-formed cavity trays – Timloc Inter-Loc
Need spacing schedules or UKCA docs? Contact us or call 0118 922 7941—Spechunter chases down every spec so you don’t have to.
Spechunter.co.uk – Chasing down specialist construction specifications since 1988. Fact checked and updated May 2025
...