Type 2 Wall Ties
The Go-To Tie for Everyday Masonry
Why pick a Type 2?
Most homes, schools and light-commercial builds sit under 15 m high and outside “very severe” wind zones. In these conditions a Type 2 tie gives all the restraint you need—0.7 kN tension / compression—without the extra cost or footprint of a heavy Type 1. Each tie below is Grade 304 (316 on request) stainless, drip-pressed to stop rain tracking and tested to BS EN 845-1 for full PD 6697 compliance.
Order before 12:00, spend £200 ex-VAT and your ties arrive next working day. Need spacing calcs? Phone 0118 922 7941—we’ll size them while you wait.
Quick-order chart – choose by cavity width
| Cavity (mm) | Tie & length | Box qty | Quick-add link* |
|---|---|---|---|
| 50–75 | Vista EN2 200 mm | 250 | EN2-200 |
| 76–100 | Vista EN2 225 mm | 250 | EN2-225 |
| 101–125 | Ancon RT2 250 mm | 250 | RT2-250 |
| 126–150 | Vista EN2 250 mm | 250 | EN2-250 |
| 151–175 | Ancon RT2 275 mm | 250 | RT2-275 |
Want an alternative brand? Check TecTies TT2 225 & 250 mm
Key features at a glance
≥0.7 kN characteristic tension & compression —approved for buildings ≤15 m in towns/suburbs.
Deep drip centred in the cavity halts water migration.
Tangle-free ends (Vista EN2) speed bricklayers—no knots in the tie bucket.
2.5 ties / m² density keeps calculations simple; just double up at reveals and movement joints.
60-year design life in Inland or Coastal Zone 1; upgrade to 316 SS for Coastal Zone 2 (≤5 km from sea).
Add red insulation-retaining clips so partial-fill boards stay flush to the inner leaf.
Installation best practice
Lay ties on a 450 mm vertical × 900 mm horizontal grid (2.5 / m²).
Embed 50 ± 10 mm in each masonry leaf; keep the drip mid-cavity.
At storey-height DPCs, lap new ties over the course below by at least one brick length.
Slip a compression sleeve over ties where cavities exceed 150 mm to curb “whip”.
Within 150 mm of openings or movement joints, double-up the ties to four per square metre.
For façade panels longer than 12 m, add movement ties every 10–12 m.
FAQs
When must I use Type 2 instead of Type 4?
Whenever the building exceeds 10 m high or sits in a “moderate” wind zone (BS 6399 / Eurocode C2). Type 4 ties suit sheltered two-storey housing only.
Are galvanised Type 2 ties allowed?
Not in external masonry—stainless only. Galv versions are limited to internal leafs or below DPC.
Can I mix brands on one elevation?
Yes, if they share the same Type 2 classification and you maintain the 2.5 / m² density.
Delivery cut-off & surcharges?
Order by noon, hit £200 ex-VAT and see delivery info for Highlands & Islands exceptions.
Related products to drop in the basket
Heavy-duty ties for exposed sites – Type 1 Wall Ties
Bed-joint crack control – Ladder Reinforcement Mesh
Pre-formed cavity trays – Timloc Inter-Loc
Need a spacing schedule, UKCA declaration or BIM object? Contact us or call 0118 922 7941—Spechunter will chase down every spec so you don’t have to.
Spechunter.co.uk – Chasing down specialist construction specifications since 1988. Fact checked and updated May 2025
...