IKO PLC

IKO’s Hyload banner has protected British buildings for almost 50 years. From the original pitch-polymer DPC that rewrote BS 8215 in the 1970s to today’s insulated DPCs and torch-on grade membranes, every roll still comes off IKO’s UK lines fully BBA-certified and ready for Building Control. Spechunter carries the lot — rolls, tapes, primers and fixings — boxed and on the shelf for next-day delivery.

Order before 12:00, spend £200 ex-VAT and delivery is free next working day.
Need the BBA cert or a take-off schedule? Ring 0118 922 7941 — we’ll sort it while the mixer spins.


Quick-pick Hyload range

ApplicationProductWidths / sizesQuick-add*
Standard masonry DPCHyload Original (pitch-polymer, 0.6 mm)100–900 mm × 20 mView range
Value housebuildingHyload Trade (polymer, 0.45 mm)450 & 600 mm × 20 mTrade DPCs
Reduce cold bridgesHyload Insulated DPC (EPS core)165 & 225 mm × 8 mInsulated DPC
Vertical tanking & slabsHyload Torch-On Membrane1 m × 8 mTorch-On
Detailing & repairsIKO Pro Synthaprufe liquid DPM25 L tinSynthaprufe 25 L
Fix DPC to blockworkHyload Fixing Strip2 m lengthsFixing Strip
Seal laps & penetrationsHyload Double-Sided Butyl Tape100 mm × 10 mButyl Tape

*Links jump straight to stocked SKUs for rapid checkout.


Why professionals still choose Hyload

  • BBA certificates on Original & Insulated DPCs (Certs 95/3133 & 06/4384) — accepted by NHBC and LABC.

  • Pitch-polymer heritage delivers outstanding flexibility at low temps and sheer tensile strength.

  • Full accessory ecosystem — fixing strips, butyl tapes and mastic let you detail trays and upstands fast.

  • Torch-on membrane bonds hot to concrete or screed for a Grade 3 BS 8102 tanking system.

  • UK-manufactured under ISO 9001 & 14001 — short lead times and reliable quality.

Team Hyload membranes with full-height weep vents and Type 1 wall ties for a complete damp-proof, structurally sound façade.


Installation snapshot

  1. Support wide DPC rolls (>450 mm) using Hyload fixing strip at 450 mm centres.

  2. Lap 100 mm minimum; bond trays or vertical joints with Hyload double-sided butyl tape.

  3. Keep the drip mid-cavity — install weep vents every 450 mm above trays.

  4. Torch-on membrane: prime concrete, heat-bond sheet, lap 100 mm side / 150 mm end laps.

  5. Insulated DPC: place the EPS core against the cavity insulation to cut linear thermal bridging at thresholds.


Frequently asked questions

Is Hyload Original still allowed over 18 m façades?
Hyload Original is class E, so Regulation 7(2) bars it from “relevant” walls above 18 m. Use Visqueen A1 Zedex instead.

Torch-on vs High-Bond self-adhesive — when to pick which?
Torch-on suits large decks and podium slabs; High-Bond excels on vertical concrete or parapets where primer-free adhesion saves time.

Shelf life on Synthaprufe liquid DPM?
12 months unopened. Stir thoroughly if stored >6 months.

Delivery cut-off & surcharges?
Order by noon, spend £200 ex-VAT. See our delivery information for Highlands & Islands.


Complete your Hyload package

Need CAD details, COSHH sheets or BS 8102 tanking advice? Contact us or ring 0118 922 7941 — Spechunter will chase down every spec so you don’t have to.

Spechunter.co.uk – Chasing down specialist construction specifications since 1988. Fact checked and updated May 2025.

...
Showing 1 - 9 of 19 items